Shrnutí obsahu

Strany 1 - Pro-200W, Pro-400W

OWNER’S MANUALPro-200W, Pro-400WPOWER INVERTERS

Strany 2 - IMPORTANT INFORMATION

TROUBLESHOOTINGTROUBLESHOOTINGPROBLEM: Low Battery Alarm On All The TimeProblem SolutionInput voltage below Keep input voltage above 10.5 volts. 10.

Strany 3

SPECIFICATIONSTROUBLESHOOTINGPROBLEM: TV Does Not WorkProblem SolutionTV does not turn on. Try rocking the ON/OFF switch of the inverter while leavin

Strany 4 - OPERATION

INVERTER BASICSGetting StartedPower equipment and appliances which operate with motorsor tubes require an initial surge of power to get them up andrun

Strany 5

INVERTER BASICSDon’t Push It.Although your WHISTLER inverter has the capacity toprovide power output (excess current) equal toapproximately two times

Strany 6 - ADDITIONAL FEATURES

OPERATIONMaking the Connection.This inverter is designed to connect to your 12 volt batteryusing the lighter socket plug or by the supplied batterycab

Strany 7 - CARE AND MAINTENANCE

• The use of an extension cord from the inverter to theappliance or equipment being operated will decrease thepower being delievered to the load. For

Strany 8 - OPERATING PRINCIPLES

ADDITIONAL FEATURESAutomatic Shut Down & Related Safety Features.Each inverter has an unique LED indicator warning lightsystem which operates in c

Strany 9

2. Low Battery Voltage Alarm/Shutdown Protectiona) When the input voltage from the 12 volt power sourcedrops below 10.5 volts, an audible tone will b

Strany 10 - TROUBLESHOOTING

OPERATING PRINCIPLESOPERATING PRINCIPLESThe majority of AC voltmeters measure RMS voltage andassume that the measured waveform will be a pure sinewave

Strany 11 - SPECIFICATIONS

• When operating the inverter with the engine off, start theengine every hour and let it run for at least 10 minutes torecharge the battery.• In the e